stack temperature question — heating help: the wall

Stack temperature question — Heating Help: The Wall

I now have an entirely straight flue with a stainless steel/titanium liner. Just finished that 3 days ago and I got a heating pro to fire the boiler and do combustion analysis this morning. I have an oil fired peerless boiler. Prior to the chimney work I had a 450 degree stack temperature. The stack temperature is much higher now at 530 degrees.

Get a Quote
proper boiler feed water temperature management | powerhouse

Proper Boiler Feed Water Temperature Management | Powerhouse

Pre-heating the feed water to achieve an ideal boiler feed water temperature will allow the boiler to run most efficiently as the heat input required to raise the temperature of the water up is reduced. The difference between 140°F and 180°F in boiler feed water temperature equates to about a 3-4% difference in boiler efficiency.

Get a Quote
boiler formulas | johnston boiler

Boiler Formulas | Johnston Boiler

Factor of Evaporation Water enters the boiler at 225°F. The boiler pressure is 100 psi and the boiler water temperature is 338°F. The latent heat is 881 Btu.

Get a Quote
improve your boiler’s combustion efficiency

Improve Your Boiler’s Combustion Efficiency

Stack gas measurements indicate an excess air level of 44.9% with a flue gas minus combustion air temperature of 400°F. From the table, the boiler combustion efficiency is 78.2% (E1). Tuning the boiler reduces the excess air to 9.5% with a flue gas minus combustion air temperature of 300°F. The boiler combustion efficiency increases to 83.1%

Get a Quote
15 ways to increase boiler efficiency in your facility

15 Ways to Increase Boiler Efficiency in Your Facility

Jul 30, 2020· Think about it; the boiler draws in cool air, heats it up, and sends it out the stack. A lower stack gas temperature is ideal because the higher the temperature, the more energy leaves with the flue gas. On the other hand, the boiler system takes in cold water, heats it to steam, and uses the heat.

Get a Quote
boiler efficiency and combustion | spirax sarco

Boiler Efficiency and Combustion | Spirax Sarco

The losses are attributable to the temperature of the gases leaving the furnace. Clearly, the hotter the gases in the stack, the less efficient the boiler. The gases may be too hot for one of two reasons: The burner is producing more heat than is required for a specific load on the boiler:

Get a Quote
boiler size calculator - what size boiler do i need

Boiler size calculator - What size boiler do I need

To get a quote on a 111-W hybrid combi boiler, use our online tool. Check our new boiler costs guide to get an idea of how much it may cost you and if you're interested in paying for your boiler monthly, refer to our boilers on finance guide. Whatever type of boiler you need, Heatable provides.

Get a Quote
rules and regulations for boiler and pressure …

RULES AND REGULATIONS FOR BOILER AND PRESSURE …

(d) Electric Boiler - A power boiler or heating boiler in which the source of heat is electricity. (e) Miniature Boiler - A power boiler or high-temperature water boiler which does not exceed the following limits: 1. 16" inside diameter of shell; 2. 20 sq. ft. heating surface (not applicable to electric boilers);

Get a Quote
combustion efficiency and excess air

Combustion Efficiency and Excess Air

1) "Net stack temperature" is temperature difference between flue gas temperature inside the chimney and room temperature outside the burner. Flue Gas Loss with Oil Combustion. The efficiency loss in the flue gas related to. temperature difference in flue gas and supply air ; CO 2 concentration in the flue gas; with oil combustion is indicated below:

Get a Quote
the temperature in your boiler and the dangers of

The Temperature in Your Boiler and the Dangers of

Once a boiler starts to go over 212°F, you can face serious problems. Watch out for overheating. If you notice that your boiler’s temperature is going higher than the above settings, you have a major problem. If a boiler has reached 220°F, a sudden drop in pressure could cause the tank to burst. Overheating also is the main cause of leaking.

Get a Quote
how much 1 ton steam boiler lpg fuel consumption

How Much 1 Ton Steam Boiler Lpg Fuel Consumption

3 ton per hour boiler gas consumption - 1 ton boiler fuel consumption 1000kg per hour steam . natural gas require per ton steam production for a boiler | So we can calculate the gas consumption per hour = 600000 Energy Tips: Benchmark the Fuel Cost of Steam Natural Gas (therm Steam, Boiler, To produce 1 ton of steam per hour, how much Water does not change its mass on going from liquid to .

Get a Quote
5 factors killing your industrial boiler efficiency & what

5 Factors Killing Your Industrial Boiler Efficiency & What

Dec 02, 2016· Net stack temperature is the difference between the flue gas temp and the ambient temperature. Although it's tempting to minimize ambient temperature with hopes of lowering flue gas temp, a 40 degree alteration in ambient temperature can affect industrial boiler …

Get a Quote
forbes marshall | steampedia | understanding stack losses

Forbes Marshall | SteamPedia | Understanding Stack Losses

What are stack losses? Constant combustion takes place inside a boiler furnace. In order to burn the fuel, oxygen is required. Hence, the burner is supplied with air. Air normally has 21% Oxygen, 78% Nitrogen and moisture content depending upon the location. The fuel which is burnt inside is composed of hydrocarbons mainly.

Get a Quote
high stack temperature, high convection section

High Stack Temperature, High Convection Section

The most common cause of high stack temperatures is running with too much excess air. If the process and temperature in the convection section are within specified limits the first item to check is the excess oxygen. If the excess oxygen is above the specified target, then steps should be taken to reduce the air coming through the burners.

Get a Quote
gas-fired boilers - code compliance brief | building

Gas-Fired Boilers - Code Compliance Brief | Building

Hot water boilers that supply heat to the building through one- or two-pipe heating systems should have an outdoor reset control that lowers the boiler water temperature based on the outdoor temperature per R403.2/N1103.2. Equipment Sizing.

Get a Quote
steam pressure reduction: opportunities and issues

Steam Pressure Reduction: Opportunities and Issues

relationship between pressure and stack temperature for a test on a 65,000 lb/hr watertube boiler operating at a constant output of 38,500 lb/hr. As tested, the boiler stack temperature varies linearly with steam pressure. A savings of 0.4% to 0.8% of the fuel input can be expected from lower stack temperature. Boiler Radiation and Convection Loss

Get a Quote
technical advice on boiler combustion control

Technical advice on boiler combustion control

Stack loss generally ranges from as much as 30 percent for a green-wood-fired boiler, to 18 percent for a typical natural-gas-fired boiler, to 12 percent for an oil-fired boiler, to as low as 9 percent for a coal-fired boiler. It must be pointed out that the stack-loss range is wide for any given fuel.

Get a Quote
chapter 10: boilers and pressure vessels, california

Chapter 10: Boilers and Pressure Vessels, California

Operative dampers shall not be placed within a stack, flue, or vent of a gas-fired boiler, except on an automatic boiler with prepurge, automatic draft control, and interlock. 1003.5 Welding Welding on pressure vessels shall be done by certified welders in accordance with nationally recognized standards.

Get a Quote
boiler operation & boiler maintenance | hsb locomotive

Boiler Operation & Boiler Maintenance | HSB Locomotive

Boiler logs are the best method to assure a boiler is receiving the required attention and provide a continuous record of the boiler's operation, maintenance and testing. Because a boiler's operating conditions change slowly over time, a log is the best way to …

Get a Quote